Water Flow Meter Dn10 Diameter and PTFE Lined Magnetic Flow Meter

RS485 integral type electromagnetic flow meterThis technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes\' diameter, and are therefore designed such that they do not disturb or restrict the flow of the m

Featured Products

Water Flow Meter Dn10 Diameter and PTFE Lining Electromagnetic Flow Meter

RS485 integral type electromagnetic flow meter

This technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns.

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have.

what's the technical parameters of magnetic electromagnetic flowmeter?

Production Name magnetic electromagnetic flowmeter
 Medium water;wastewater;Mud and varioue kinds of conductivity liquid
 Diameter DN10~DN2000mm
 Accuracy +/-0.5%
 Temperature <80ºC(rubber); <180ºC(PTFE)
Pressure 4.0Mpa(DN10~80);1.6Mpa(DN100~150);1.0Mpa(DN200~1000);0.6Mpa(DN1200~2000)
 Flow speed 0.3~10m/s
 Requirement of   pipeline Upstream ≥5DN;Downstream≤3DN
 Electrode Stainless steel 316L(standard);Titanium;Tantalum;Hastelloy
 Lining PTFE;Rubber
 Connection Flange;thrad;clamp on
 Body material Cast steel ;stainless steel 
 Power supply 220V;24V;Battery
 Output Pulse;4~20mA;HART;RS485;MODBUS;GPRS
 Communication HART;RS485;MODBUS
 Explosion proof Customized 
 Protection IP65 or IP68
 Environment Environment:-20~60ºC
 Power <20W

Water Flow Meter Dn10 Diameter and PTFE Lining Electromagnetic Flow Meter

 Item The Electrode table
 Material The Medium
 SS316L  For:Living water; wastewater;Corrovise water and Mud,etc;
 Hastelloy B  For:Non-oxidizing acids at concentrations less than 10%;NAOH Concentrations less than 50%
 Hastelloy C  For:Mixed Acid and Oxidizing salts
 Titanium  For: Salt and weak acid ;Not application:hydrochloric acid, nitric acid and other reducing acids
 Tantalum  For:hydrochloric acid(<40%);Sulfuric acid and Other oxidizing acids
 Plantinum  For:Almost all acid-base salt solution But not application for aqua regia, except ammonium salt
Tungsten carbide  For:Pulp ;sewage ;slurry

Water Flow Meter Dn10 Diameter and PTFE Lining Electromagnetic Flow Meter
Water Flow Meter Dn10 Diameter and PTFE Lining Electromagnetic Flow Meter

[Installation]

 1.Installation location

  • Avoid the magnetic objects and equipment with stong electromagnetoc field;
  • should installa the flow meter at ventilated location;
  • Avoid the location wherer ambient temperature above 50ºC and relative humidity above 90%;
  • The water flowmeter should be installaed at somewhere spacious;
  • The DH1000 series Digital Electromagnetic Water Flow Meter with RS485 Signal should be installaed behind pump and the value should installa at downstream.            

    2.Installa the flow sensor

  • Must to ensure the pipeline is fulled and without bubbles to keep the high accuracy;
  • The flow direction shoudl keep with sign on the body of flowmeter;
  • Ensure the double electrodes keep Horizontal;
  • If the medium is mixed by liquid and solid,Pls installa it at vertical to extend the working life of lining;
  • If the environment with shocked pls installa the bracket at both front and behind;
  • If the medium is pollution liquid,should installa the flow meter at bypass pipe and don't interrupted when you on service;

   3.Requirement of Straight pipe

  • The straight of pipe at inlet must more than 10×DN,Suggest 15DN;at outlet,the straight pipe at least 5×DN;
  • If at the upstearm of flowmeter,there are values,elbow,the straight must need 15×DN;
  • Pls installa the shut-off value at both front and behind of flow meter; 

  4.Installation advance

  • The installation location for you reference 
Water Flow Meter Dn10 Diameter and PTFE Lining Electromagnetic Flow Meter[Company Information]
  • Our Company is Top 10 Manufacture on Alibaba;
  • We have about 30 years of experience in Manufacture;
  • Our products have been exported to more 100 coutries and area;
  • ISO,SGS,CE and more ceterficates for you reference;
  • Patent technology and more than 3 years working life
Water Flow Meter Dn10 Diameter and PTFE Lining Electromagnetic Flow Meter
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours